Infrared Carbon Sulphur Analyser used in Building Materials

Carbon: 0.0001%-10.0000% (can be expanded to 99.9999%)
Sulfur: 0.0001%-3.5000% (can be expanded to 99.9999%)
Convenient, practical, reliable
Automatic burner cleaning device
It adopts multi-level hidden circuit
Spectral characteristics of high efficiency
Automatic detection of solenoid valve
Simplify design, smaller size

  • Product Detail
  • Video

Summary:

CS-8820 is suitable for multi field and all around. Carbon and sulfur analyzer combines with high-frequency induction burner, it is a high-tech product the which based on light, machine, electricity, computer, analytical skills, it has characteristics of wide measuring range and the results of analysis is accuracy and reliable. Because of adopting computer technology, intelligent equipment, screen display, text and data collection, deal with problems and so on have reached the advanced the world level, more industries detect carbon and sulfur elements in this analysis equipment. The key components adopt high quality elements to ensure the instrument stability and high quality.

 

Application:

CS-8820 High-Frequency Infrared Carbon & Sulfur Analyzer is used to measure mass fraction of carbon and sulfur in steel, iron, alloy, casting core sand, nonferrous metals, cement, ore, coke, catalyst, magnetic materials, ceramics, inorganic matter, graphite, refractory materials, battery materials, plants and other materials. And mainly used in new energy, metallurgy, mechanical, mine, inspection, nuclear industry, coal, automobile, shipping, aviation, food, aerospace, building materials, university, geology, petrochemical and so on. 

 

Feature:

Infrared Carbon & Sulfur Analyzer
1.Circuit: The entire device adopts double-CPU design, with high-integration electronic circuits to achieve stability and reliability. Meanwhile, it adopts multi-level concealed separation circuit using optical fiber transmission to thoroughly solve the problem of high-frequency interference.
2.Power: Industrial integrated linear modular power provides stable power output with no malfunction.
3.Light Source: Special new platinum infrared light source generates continuing heat and has high spectral efficiency.
4.Analysis Pool: Gilded carbon and sulfur analysis pool and high-precision pyroelectric infrared detectors.

High-Frequency Combustion Furnace
1.High-Frequency Circuit: High-power high-frequency circuit design and ceramic vacuum capacitor can help system do vacuum combustion without samples so that the system reduces load of high-frequency combustion system and improves service lifespan.
2.Control Circuit: Automatic detection of electromagnetic valves, lifting cylinders and high-frequency working conditions.
3.Safety System: Automated overtime and overflow alarm ensures high-frequency furnace under normal condition.
4.Gas Path Structure: Inlet Gas Path System (electromagnetic valves, pipe joints and lifting cylinders) can automatically check leakage.
5.Dust Removal System: Furnace end auto-cleaning device and patent technology of ash discharge system. The dust removal system adopts to achieve good airtightness and purification as well as convenient replacement. It can reduce impact from dust on analysis results. 
6.Furnace Body Structure: Low-pressure heating and furnace end constant temperature improves conversion rate of sulfur and makes the analytical results of sulfur stable.

Random Software
1.Analysis Passage: The software provides the function of passage management so that passages of carbon and sulfur can automatically add, delete and edit without limitations in number.
2.Sample Management: It is available to edit names and marks of samples, and add and delete sample names.
3.Display Function: A curve box for carbon and sulfur each. The system monitors real-time data and release curves of carbon and sulfur during the process of analysis.
4.Data Processing Function: The analysis results are stored by ACCESS database. It is available to store all data and curves from every analysis of carbon and sulfur.
5.Search Function: Users can search in terms of time, operators, sample names and marks.
6.Software Function: The system provides multiple functions such as curve/data storage, void removal, parametric settings, passage selection, mathematical statistics, result correction and curve comparison. 
7.Printing Function: Printing modes diversify. The system provides two printing modes, i.e., testing laboratory and detection station, and users can voluntarily design printing formats.
8.Self-Diagnostic Function: The software can realize airtightness of furnace end and gas chamber.

Configuration of Computer and Printer
1.Microcomputer: Brand commercial microcomputers.(Mainstream standard configuration, can be selected according to user requirements)
2.Printer: Laser printer (A4 paper) (Mainstream standard configuration, can be selected according to user requirements).
Electronic Scales

 

Parameter:

Item

Index

Measuring range

C:0.0001%-10.0000% (can extend to 99.9999%)

S:0.0001%-3.5%000% (can extend to 99.9999%)

Analysis of error

With GB/T20123-2006/ISO15350:2000standard

Analysis time

25-60seconds can be set (usually 35 seconds)

High frequency furnace

Power≥2.7KVA oscillation frequency:20MHz

Electronic balance

Weight the sample in variable amount accuracy of reading: 0.0001g

Working environment

Indoor temperature: 10℃-30℃; relative humility: <90%

Power supply

Voltage: AC220V±5%, frequency50Hz±2%

Oxygen

Purity:≥99.5%,input pressure:0.18Mpa+5%

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related products
Carbon Sulfur Analyzer
CS-8820 High Frequency Carbon and Sulfur Analyzer

Carbon: 0.0001%-10.0000% (can be expanded to 99.9999%)
Sulfur: 0.0001%-3.5000% (can be expanded to 99.9999%)
Convenient, practical, reliable
Automatic burner cleaning device
It adopts multi-level hidden circuit
Spectral characteristics of high efficiency
Automatic detection of solenoid valve
Simplify design, smaller size

Technical Cleanliness Inspection
CA56 Technical Cleanliness Analysis System

Professional instruments, standardization

Analysis process based on ISO16232, VDA19 

High-performance particle size testing system

Test results traceable,generate results and reports

Simple operation, capture images fast and efficient

Automatic compensation ,each  image is clear, seamless browsing

Used in auto parts, aerospace, and hydraulic lubrication industries

Satisfy Volkswagen, BMW, GM, Ford and other major automakers

metal analyzer
W6 Vacuum Arc Spark Optical Emission Spectrometer

CMOS-based, spark discharge, optical emission spectrometer

Multi-bases, full spectrum analysis for utmost elemental flexibility

Ultra-low limits of detection 

Wavelength range:130nm-800nm, maximum 30+ elements

Long-term stability and repeatability

Excellent vertical optical emission spectroscopy

Vacuum gauge to monitor the vacuum status in real time

Ultra-low carbon, low nitrogen analysis

Small sample analysis applications

metal analyzer
Arc Spark Optical Emission Spectrometer used in Steel Industry

The 4th Generation High Performance Metal Analyzer

CMOS-based, spark discharge, metal detection

Ultra-low limits of detection

High integration, reliability, stability

Lowing operating cost and easy maintenance

Vacuum optical chamber and low argon consumption

Argon jet technology to optimize small sample analysis

Standardized parameter modification

Maximum 30+ elements

High nitrogen (N) analysis 0.03-0.9%

metal analyzer
Spark OES Spectrometer used in Metallurgy

TY-9000 Optical Emission Spectrometers (Arc/Spark-OES)

CCD-based, spark discharge, metal analyzer.

Precise analysis of all common metals for incoming and outgoing product quality control.

Effective wavelength range: 130nm-800nm.

Superior scalability to meet the needs of business expansion

Rugged and reliable,

Easy to operate  

Available as benchtop or floor model

metal analyzer
Metal Analysis Direct Reading Optical Emission Spectrometer

CMOS-based, spark discharge, optical emission spectrometer

Multi-bases, full spectrum analysis for utmost elemental flexibility

Ultra-low limits of detection 

Wavelength range:130nm-800nm, maximum 30+ elements

Long-term stability and repeatability

Excellent vertical optical emission spectroscopy

Vacuum gauge to monitor the vacuum status in real time

Ultra-low carbon, low nitrogen analysis

Small sample analysis applications

XRF Analyzer
P9800S Benchtop XRF Analyzer

Cl, K, Si, Mg, Al, S, P, Ca, Fe in cement and Limestone

Upper-illuminated optical path structure

High precision, good stability, simple operation

Test results close to wet chemical method testing

Only a few minutes to analyze dozens of elements in a sample

VDA19 Testing Laboratory Goggles
VDA19 Testing Laboratory Goggles

Material: Polycarbonate lens

180-degree curved design for a clear field of view

Three-position temple adjustment for a comfortable fit

Frame/tem length: 136/145mm

Height/weight: 52mm/36g

Leave A Message
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

skype

whatsapp