VDA19.1 Technical Cleanliness Analysis System CA53M

Carried Standards: VDA19, ISO16232, NAS1638, ISO4406 and other standards.

Analysis Time: Less than 5 minutes.

Particle Size: ≥5um

Particle Height: Particle height can be measured.

Focus Mode: Automatic focus, no human intervention.

Repetition Accuracy: Above 99% (membrane scanned repeatedly for 10 times)

Scanning Mode: Aotomatic scanning

Particles Identify: Metallic particles, non-metallic particles, fibers.

  • Product Detail
  • Video

Summary

This analysis system is used for cleanliness testing of automotive component samples. It can automatically count and analyze the type, size, and quantity of contaminant particles on the filter membrane, and classify them by size grade.

It meets the specification requirements for component cleanliness testing of powertrain plants such as VDA19, ISO16232, NAS1638, ISO4406, ISO4407, as well as those of Volkswagen, BMW, Ford, Mercedes-Benz, General Motors, etc. It can issue standard data reports compliant with the above specifications and has the capability to customize data reports.

 

Application

CA53M Technical Cleanliness Analysis System full compliance with the requirements of VDA 19.1-2015, ISO 16232, ISO4406 and ISO 4407, QV11111 and customer-defined standards. Adopted optical polarization technology, manually rotate the polarization device, the metallic luster reflection properties of all pollutants on the entire filter can be determined by two scans. At the same time, according to the morphological definition of fiber in VDA19.1 (stretch length/maximum inscribed circle diameter>20, maximum inscribed circle diameter≦50 microns), the classification and classification of the following four types of particles can be quickly and automatically completed within a few minutes. Size measurement: reflective particles, reflective fibers, non-reflective particles, non-reflective fibers.


Performance Features

1.The scanning and evaluation time for a single filter membrane should be controlled within 3 minutes (under the condition of a 3× objective lens, with a total magnification of no less than 250×).

2.The analysis can accurately distinguish metal particles, non-metal particles, and fibers, so as to have standard data basis for judgment.

3.The research-grade stereomicroscope with high depth of field, by virtue of its ultra-high depth of field and the new 4th-generation filter membrane clamping device, perfectly solves the problem of failure to capture all sharply focused images during scanning caused by the uneven surface of the filter membrane.

4.The software interface can be switched between Chinese and English.

5.The equipment automatically adjusts light intensity, performs multi-field automatic scanning, automatically collects images, and conducts automatic particle statistical analysis.

6.The equipment can accurately and automatically focus on and calculate the sizes of both large and small particles in the same scanning area.

7.It can classify and determine grades according to length grades based on ISO16232-2018, VDA19-2015, NAS1638, ISO4406, ISO4407 and enterprise-defined standards, and can calculate the total length of fibers on the filter membrane. 

8.In accordance with the ISO16232/8 grade setting, when the same standard sample is tested repeatedly for 10 times, the deviation of the total number of particles is less than 10%.

9.According to customer requirements, particles of different sizes ranging from 5μm to 3000μm and above can be classified, counted and evaluated.

10.It can also accurately identify large particles with a diameter of more than 2mm. The system can automatically measure and calculate the size parameters of a single particle, such as area, width, and inscribed circle.

11.Operators can freely add the functional items that need to be reflected in the report in the software, and the software has an automatic memory function. It abandons the traditional way of selecting the corresponding template.

12.After scanning the filter membrane, it should have the capabilities of automatic particle statistics, automatic thresholding, and automatic particle identification without human intervention to reduce misoperations. However, it retains the functions of manually modifying the scanning results so as to splitting or associating particles of any shape.

13.Image acquisition device: a color high-definition camera, which can cooperate with an automatic microscope to perform automatic color balance, automatic scanning, and automatic image acquisition.

14.The system should have the ability to restore the color of particles to facilitate the naked eye to distinguish particles with different metal colors.

15.After a single scanning and evaluation, the software should be capable of reselecting the analysis area for re-analysis (this action should not require re-scanning the filter membrane), so as to extract particles that may be lost at the edge of the filter membrane.

16.Equipped with a high-precision automatic scanning stage with free travel, featuring both automatic and manual control modes. The overall accuracy of the scanning stage and equipment as well as the detection results are ultimately controlled by standard blocks.

17.The cleanliness analysis report shall include product model, customer name, inspection requirements, inspection date, inspection equipment model, inspector, inspection pictures, evaluation results, etc. The cleanliness analysis report can be saved and printed.

18.Evaluate the total number of contaminants per filter membrane, the total number of contaminants per part, and the total number of contaminants in the projected area of 1000cm² proposed in the evaluation results according to VDA19-2015, and present them in the form of a report.

19.The software can automatically stitch scanned images and store the scanned image of the entire filter membrane; the stored filter membrane images can be retrieved at any time for re-analysis, storage, and automatic export of office and word reports; the particle grades in the report template can be set according to user needs.

20.Equipped with a dedicated filter membrane holder. Once the filter membrane is placed, it can be directly scanned without repositioning, and it is compatible with filter paper specifications ranging from Ф47mm to Ф50mm.

21.The scanning data performance of nylon mesh woven membranes is the same as that of surface filter membranes, and the results are not affected by the mesh.

22.System calibration ruler, specification: 1/100μm

23.To ensure the reliability of equipment accuracy, standard slices (OPTO particle standard slices) used by benchmark host factories shall be provided for scanning and verifying the equipment, which are used for calibrating the equipment accuracy.

 

Technical Parameter

CA53M Technical Cleanliness Inspection System

Microscope

 Upright Metallographic Microscope BX53M

Vertical illuminator

Standard 5X and 10X objectives

Optical magnification: 50-100x

Pixel magnification: approximately 450x(Under the condition of 5X objective lens)

Camera

CMOS Sensor

Effective pixels: 230W

Interface type:USB3.0

Resolution: 1920 × 1200

Pixel size: 5.6*5.6μm

Resolution: 0.5um/pxi

Frame rate:40 frames

Light Source

Industry-unique dual polarization

Fully automatic polarization switching

Software automatic control

Motorized Platform

X, Y, Z-axis fully automatic control scanning stage: Repeatability ≤2μm; Stroke: 80mm*60mm; Maximum speed ≥100mm/s; Minimum step ≤200nm

Z-axis resolution: 0.1μm. Stroke height: 50mm

Particle Standard Slide

Model: opto

Material: glass

Number of particles: 224 (higher than 64 in the industry)

Maximally simulate the actual morphology of particles

Particle shapes: circular, hollow circular, elliptical, rectangular, S-shaped, etc.; not a single straight line

Computer

Operating system: Windows 10/64-bit; computer hardware configuration not lower than: CPU-I5 octa-core, 1TB HD, 16GB memory, 1TB hard drive, 21.5-inch HD display

Software

Professional cleanliness analysis software with functions including one-click operation, repeated positioning of each particle, particle statistics, automatic evaluation, one-click export of professional reports, etc., lifetime free upgrade

Repeatability

Repeatability ≥98% after scanning the filter membrane ten times

Detection Accuracy

Actually measured to detect particles ≥5μm

In accordance with VDA19.1 standard, it is recommended to analyze particles ≥15μm with a stereomicroscope (with a zoom ratio ≤16:1)

Scanning Method

One-click fully automatic scanning, automatic generation of particle data, and one-click report export

Analysis Duration

For filter membranes with a diameter of 47/50mm, the time from a single analysis to result output is no more than 3 minutes

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related products
ISO16232 Technical Cleanliness Analysis System CA15A
ISO16232 Technical Cleanliness Analysis System CA15A

Carried Standards: VDA19, ISO16232, NAS1638, ISO4406 and other standards.

Analysis Time: Less than 3 minutes.

Particle Size: ≥15um

Repetition Accuracy: Above 98% (membrane scanned repeatedly for 10 times)

Scanning Mode: Aotomatic scanning

Light Source: Software controlled automatic double polarized mode.

Particles Identify: Metallic particles, non-metallic particles, fibers.

Automotive Cleanliness Inspection Electronic Cooling Oven
Automotive Cleanliness Inspection Electronic Cooling Oven

It is used to store filter membranes and provide the function including cooling, moisture-proofing, mildew-proofing, and oxidation prevention, as well as effectively reducing humidity.

Optical Emission Spectrometer
W4 Arc Spark Optical Emission Spectrometer

High resolution CMOS readout system

Low total cost of ownership

Vacuum optics enabling fast stabilization

Excellent long-term stability

Intelligent design, Modular design

Ferrous and non-ferrous applications

Easy to use with full PC control

Friendly user interface

Spectrometer for Metal Analysis
CCD Optical Emission Spectrometer for Metal Analysis

CCD-based, spark discharge, metal analyzer.

Precise analysis of all common metals for incoming and outgoing product quality control.

Effective wavelength range: 130nm-800nm.

Superior scalability to meet the needs of business expansion

Rugged and reliable,

Easy to operate  

Available as benchtop or floor model

onh analyzer
ONH Oxygen Nitrogen Hydrogen Analyzer

Oxygen: 0.00005%~0.1%

Nitrogen: 0.00005%~0.5%

Hydrogen: 0.00005%~0.0050%

Optimized with user-friendly features

Highest Reliability and Economics

Precise and efficient element analysis

Quick results thanks to easy operation

Powerful furnace technology and new sample port system

Oxygen measurement cells with flexible measuring range 

Component Cleanliness Analyser Cabinets
CC767Pro Component Cleanliness Cabinets

Reliable Component Cleanliness Extraction Equipment

Ease of operation

Controlled extraction environment (laminar flow cabinet)

Programmable setting capabilities

Less human errors involved

No risk from environmental cross contamination

Reduced risk of operator contamination

Fit your available space and size of components

Disposable Cleanliness Lab Cap
Disposable Cleanliness Lab Cap

Lightweight and breathable

Resists hair loss, dust, and oil smoke

Lightweight and durable, no linting

Resists shedding, soft and comfortable

100 pieces per pack

Material: Non-woven fabric

icp aes
ICP AES used in Medicine Industry

Simultaneous ICP-OES for elemental analysis of liquids

Wavelength range:195-800nm

For 70 trace elements and macroelements

Analyze up to 600 samples per day

Low operating costs

Intuitive operation

Ultra-low limits of detection

Ultra-high speed of measurement

Leave A Message
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

skype

whatsapp