banner

Carbon Sulfur Combustion Analyser for Organic and Inorganic Samples

High-end Carbon & Sulfur Analytical Equipment

Carbon: 0.000001%~99.999999%
Sulfur: 0.000001%~99.999999%
Available for low carbon and high sulfur

Available for two carbon range two sulfur range

Easy to operate
Carbon dioxide device
Carbon monoxide conversion
Automatic detection of solenoid valve

Key Applications: Mainly used in cement, ore, coke, catalyst, magnetic materials, ceramics, inorganic matter, graphite, refractory materials, battery materials, plants and other materials.

  • Product Detail
  • Video

Summary:

CS-8800S High-frequency Infrared Carbon & Sulfur Analyzer is suitable for multi field and all around. Carbon and sulfur analyzer combines with high-frequency induction burner, it is a high-tech product the which based on light, machine, electricity, computer, analytical skills, it has characteristics of wide measuring range and the results of analysis is accuracy and reliable. Because of adopting computer technology, intelligent equipment, screen display, text and data collection, deal with problems and so on have reached the advanced the world level, more industries detect carbon and sulfur elements in this analysis equipment. The key components adopt high quality elements to ensure the instrument stability and high quality.

 

Application:

CS-8800S High-frequency Infrared Carbon & Sulfur Analyzer is used to new power energy, metallurgy, mechanical, mine, inspection, nuclear industry, coal, automobile, shipping, aviation, building materials, university, geology, petrochemical and so on. It is used to measure mass fraction of carbon and sulfur in steel, iron, alloy, casting core sand, nonferrous metals, cement, ore, coke, catalyst, magnetic materials, ceramics, inorganic matter, graphite, refractory materials, battery materials, plants and other materials.

 

Features:

Infrared Detect System
The circuit design: the whole machine adopts modular design, highly integrated electronic circuits, it is very stable and reliable, meanwhile, it is adopted multi-level isolation so as to resolve high frequency interference thoroughly.
Sampling: it is adopted 32-bit sampling chip which belongs to America Analog Devices Company so it has fast speed and high precision.
The Communication: it is adopted USB new data exchange technology, so it greatly improves the communication speed.
The Power Supply: it is adopted high quality linear integrated military-grade power module, its output stable and there is no problem.
Light Source: special new type platinum infrared light source, it is efficient and its spectral stability.
The Analysis of pool: Gold-plated carbon and sulfur analysis pool and High-precision pyroelectric infrared detector.
The Motor: special aviation motor, its thermal stability well, it has a long service life.

 

High-frequency Burning System
High Frequency Circuit: it is adopted Self-excited directional coupler take power feedback, it ensures that output power is consistent, and it makes samples fully burned. It is stable.
High-frequency High Power Circuit Design: it is adopted 7.5kvA high-frequency pipe( actually its use power more than 2.5kvA, can not add sample with empty burn), it is reduced the load on high-frequency combustion systems, and it improves service life.
Military Products: Ceramic high-power tube and ceramic vacuum capacitor (100A).
High-frequency control circuit: It can detect the electromagnetic valve itself, lifting cylinder and the working conditions of high-frequency furnace.
1, The main circuit over-current and timeout protection: it ensures that high-frequency furnace has a normal working conditions.
2, The analysis of air flow volume adopts high precision flowmeter, the results of analysis is more stable and reliable.
3, High-frequency furnace has metal filter with micropore, it ensures that dust and gas completely separated.
4, Air pressure burner automatic cleaning device, it clean it up thoroughly, to reduce the impact of dust on the result of the analysis.

 

Parameter:

Items

Index

Analysis theory

High-frequency furnace burn infrared absorptive detection.

Range of measurement

C: 0.000001%99.999999%

S: 0.000001%99.999999%

Analytical error

Accord with ISO9556/ ISO4935/ JJG395-97

Analysis precision

C:≤RSD0.5%. S:RSD≤1.0%

Sensibility (Min. reading)

0.01ppm

Detection point

Carbon: Carbon cell (can add low carbon cell)

Sulfur: Sulfur cell (can add high sulfur cell)

Time of analysis

20-60s can setting (usually 35s)

High-frequency furnace

Power≥2.5KVA—7.5KVA oscillation frequency:20MHz

Electronic balance

Weight the sample in variable amount

Accuracy of reading:0.0001g

Working environment

Indoor temperature: 10℃30℃

Relative humidity:75%

Voltage:AC220V±5%

Frequency50H±2%

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related products
Carbon Sulphur Analysis
High Frequency Infrared Carbon Sulfur Analyzer for Ore Industry

High-end Carbon & Sulfur Analytical Equipment

Carbon: 0.000001%~99.999999%
Sulfur: 0.000001%~99.999999%
Available for low carbon and high sulfur

Available for two carbon range two sulfur range

Easy to operate
Carbon dioxide device
Carbon monoxide conversion
Automatic detection of solenoid valve

Key Applications: Mainly used in cement, ore, coke, catalyst, magnetic materials, ceramics, inorganic matter, graphite, refractory materials, battery materials, plants and other materials.

Carbon Sulphur Analysis
CS-8800S High Frequency Infrared Carbon Sulphur Analyser

High-end Carbon & Sulfur Analytical Equipment

Carbon: 0.000001%~99.999999%
Sulfur: 0.000001%~99.999999%
Available for low carbon and high sulfur

Available for two carbon range two sulfur range

Easy to operate
Carbon dioxide device
Carbon monoxide conversion
Automatic detection of solenoid valve

Key Applications: Mainly used in cement, ore, coke, catalyst, magnetic materials, ceramics, inorganic matter, graphite, refractory materials, battery materials, plants and other materials.

wholesale metallographic consumables
Metallographic Cold Mounting Resin

Like various cold embedding resins, crystal glue can be easily peeled off after curing. The experimental operation is simple. You only need to pour the sample and cured resin or crystal glue into the model. It is economical and applicable, and the mold body is moderate, saving the cost of cold mounting materials. Reuse saves the cost of slicing molds.

crms material
ARMI Certified Reference Materials

Fe-based Certified Reference Materials

Ni-Based Certified Reference Materials

Cu-Based Certified Reference Materials

Al-Based Certified Reference Materials

Mg-Based Certified Reference Materials

Sn-Based Certified Reference Materials

Pb-Based Certified Reference Materials

technical cleanliness vda 19
Technical Cleanliness VDA 19 Automotive Analysis Solutions for Parts

Complete Solution for Optical Particle Analysis and Technical Cleanliness

Automatic filter analysis system

Make your technical cleanliness easier

Contamination removal and analysis

Fast live analytics and review

Full system integration for high performance

Modern cleanliness analysis systems with intuitive software

Component Cleanliness Analyser Cabinets
CC767 Component Cleanliness Cabinet

Reliable Component Cleanliness Extraction Equipment

Ease of operation

Controlled extraction environment (laminar flow cabinet)

Programmable setting capabilities

Less human errors involved

No risk from environmental cross contamination

Reduced risk of operator contamination

Fit your available space and size of components

Single crystal diamond polishing slurry wholesale
Single crystal diamond polishing slurry

Diamond suspension polishing fluid is suitable for automatic grinding and polishing machines. It has good suspension performance and the abrasives are suspended in the liquid for a long time. And polishing lubrication coolant is added to the liquid. The sample can quickly reach the desired finish after polishing.

XRF Analyzer
Full Elemental Cement XRF Device

Cl, K, Si, Mg, Al, S, P, Ca, Fe in cement and Limestone

Upper-illuminated optical path structure

High precision, good stability, simple operation

Test results close to wet chemical method testing

Only a few minutes to analyze dozens of elements in a sample

Leave A Message
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

skype

whatsapp