menu
banner

ONH Oxygen Nitrogen Hydrogen Analyzer

Oxygen: 0.00005%~0.1%

Nitrogen: 0.00005%~0.5%

Hydrogen: 0.00005%~0.0050%

Optimized with user-friendly features

Highest Reliability and Economics

Precise and efficient element analysis

Quick results thanks to easy operation

Powerful furnace technology and new sample port system

Oxygen measurement cells with flexible measuring range 

  • Product Detail
  • Video

Summary:

ONH-2018 Series Oxygen Nitrogen Hydrogen Analyzers are professional laboratory analytical instrument with high sensitivity, high precision and high stability. Due to the modular design, future hardware and software upgrades are convenient. it is used to analyze oxygen, nitrogen and hydrogen concentrations in inorganic sample materials reliably, accurately and safely by inert gas fusion.

 

Application:

The ONH-2018 series Oxygen Nitrogen Hydrogen Analyzers are used to analyze oxygen, nitrogen and hydrogen concentrations in inorganic sample materials reliably, accurately and safely by inert gas fusion. Determination of oxygen, nitrogen and hydrogen in Iron, Steel, Cobalt, Nickel, Ferroalloys, Copper Production,Titanium, Zirconium and other Refractory Metals, Metal Processing, Aluminum and Magnesium, Magnetic Materials. For example, Determining the amount of oxygen and nitrogen is critical during the steel making process, the final alloy adjustment by addition of ferroalloy but also for the production of nickel- and cobalt-base alloys.

 

Features:

1. Digital closed-loop control pulse electrode furnace

2. Powerful 8.0KW impulse furnace for temperatures in excess of 3000℃

3. Temperature programming control power, with constant power, constant current, constant voltage, slope control and other ways to increase temperature

4. Instrument operation control circuit and data acquisition adopt modular, no drift design

5. The integrated design of the whole machine, the layout is more reasonable, and the gas system is more airtight

6. It has a high functionality, elegant design and innovative features

7. It is a reliable and precise measurement of Oxygen, Nitrogen, Hydrogen is an important part of quality control process.

8. It can available for the determination of single elements as well as for measuring combinations of ON, OH, and ONH.

9. The scientific concept of the ONH-2018 series is based on flexible configuration options and the user-friendly software.

10. Quick results thanks to easy operation

11. The gas system is lead to the detectors to guarantee low detection limits and good reproducibility.

12. The ONH-2018 during analysis breaks helps to reduce carrier gas consumption and hence operating cost.

13. The controlled catalyst with moisture filter ensures reliable oxygen measurement also for low concentrations.

 

Parameter:

Item

Index

 

The Scope of Analysis

Oxygen: 0.00005%~0.1%

Nitrogen: 0.00005%~0.5%

Hydrogen: 0.00005%~0.0050%

The Minimum Reading

0.000001%

Instrument Accuracy

Oxygen: SD:≤0.0001% or RSD≤1.0%

Nitrogen: SD:≤0.0001% or RSD≤1.0%

Hydrogen: SD:≤0.2ppm or RSD≤2.0%

The Time of Analysis

Oxygen: 120~180s

Nitrogen: 120~240s

Hydrogen: 120~180s/120~240s (Infrared absorption method / thermal conductivity method)

The electronic balance weighing accuracy (One ten thousandth)

 

0.0001g

 

The Method of Analysis

Oxygen: Infrared absorption method

Nitrogen: Thermal conductivity

Hydrogen: Infrared absorption method / thermal conductivity method

 

Pulse Heating Furnace

 

Maximum current: 1500A

Maximum power: 8KVA

Maximum temperature: 3500℃

Carrier Gas

99.999% High purity argon / high purity helium,0.40MPa

Power Gas

 

Ordinary nitrogen or purified compressed air (de-oil removal), 0.25MPa.

Chemical Reagent

Magnesium perchlorate, alkali asbestos

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related products
onh analyzer
ONH-2018 Oxygen Nitrogen Hydrogen Analyzer

Oxygen: 0.00005%~0.1%

Nitrogen: 0.00005%~0.5%

Hydrogen: 0.00005%~0.0050%

Optimized with user-friendly features

Highest Reliability and Economics

Precise and efficient element analysis

Quick results thanks to easy operation

Powerful furnace technology and new sample port system

Oxygen measurement cells with flexible measuring range 

Nitrile Gloves Applied in Technical Cleanliness Extraction Laboratory
Nitrile Gloves Applied in Technical Cleanliness Extraction Laboratory

Waterproof, oil-proof, acid- and alkali-resistant

Tough, durable, and unbreakable

Material: Nitrile

Highly elastic, soft against the skin

Thickened seal, leak-proof

Powder-free

xrf analyzer supplier
JX5 Handheld XRF Metal Analyzer

The fastest handheld XRF analyzer.

Grade identification in 1 second for any metal.

Full chemistry testing in 3-5 seconds for stainless steel and other alloys.

Full chemistry testing in 7-8 seconds for aluminium alloy.

icp aes
Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES)

Simultaneous ICP-OES for elemental analysis of liquids

Wavelength range:195-800nm

For 70 trace elements and macroelements

Analyze up to 600 samples per day

Low operating costs

Intuitive operation

Ultra-low limits of detection

Ultra-high speed of measurement

libs analyzer
Portable LIBS Metal Analyzer

The Fastest Laser Metal Analyzer

Fast. Durable. Accurate.

Reliable, high-productivity metal grade analysis in only 1 second for most alloys

Idea for scrap metals sorting

Positive Material Identification (PMI)

Safe and nonradiative

Low owner cost

Especially for aluminium alloy grade and composition analysis

 

component cleanliness
CC1299Pro Component Cleanliness Cabinets

Reliable Component Cleanliness Extraction Equipment

Ease of operation

Controlled extraction environment (laminar flow cabinet)

Programmable setting capabilities

Less human errors involved

No risk from environmental cross contamination

Reduced risk of operator contamination

Fit your available space and size of components

icp aes
ICP AES Atomic Emission Spectrometer for Metal

Simultaneous ICP-OES for elemental analysis of liquids

Wavelength range:195-800nm

For 70 trace elements and macroelements

Analyze up to 600 samples per day

Low operating costs

Intuitive operation

Ultra-low limits of detection

Ultra-high speed of measurement

Technical Cleanliness Laboratory Glass Baking Containers
Technical Cleanliness Laboratory Glass Baking Containers

Material: Transparent borosilicate glass

High-temperature resistant

Smooth surface, high transparency

Easy to use with stable material

Lid/base diameter: 64/60mm

Leave A Message
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

skype

whatsapp